16.0 On-board weighing systems—Generalities

The following requirements apply only to on-board weighing systems.

16.1 On-board weighing systems are restricted to class III, IIIHD and IIII

16.2 e must be less than or equal to 5 g for class III on-board weighing systems

16.3 equipped with a means to blank the weight indications and prevent the transmission, printing and storage of the weight results when the registrations are no longer within the applicable limits of error.

16.4 Neither gross values nor tare values shall be entered manually in on-board weighing systems.