CS-03, Part II — Requirements for Terminal Equipment Intended for Connection to 1.544 Mbps (DS-1) Digital Interfaces (sf10438)

Images

Figure 3.2: 1.544 Mbps Pulse Repetition Rate Measurement

Figure 3.2 describes the test circuit to verify the free-running pulse repetition rate of the terminal equipment.

Back to document

Figure 3.3(a) (Ref. EIA/TIA 547-1989): Isolated Pulse Template and Corner Points for DSX-1 Equipment

Figure 3.3(a) specifies the shape of an isolated output pulse for approved terminal equipment.

Back to document

Figure 3.3(b): 1.544 Mbps Pulse Template Measurement

Figure 3.3(b) describes the test circuit to record a single positive pulse. The recorded pulse shape has to meet the criteria specified in Figure 3.3(a). The same circuit is used to record a single negative pulse. Both positive and negative pulses shall comply with the specified pulse mask.

Back to document

Figure 3.4: 1.544 Mbps Output Power Measurement

Figure 3.4 describes the test circuit to verify the output power of an all ones unframed digital signal in the 3 kHz bands centred at 772 kHz and 1.544 MHz.

Back to document

Figure 3.5(a): 1.544 Mbps Signalling Duration Measurement

Figure 3.5(a) describes the test circuit to verify the minimum active signalling duration.

Back to document

Figure 3.5(b): 1.544 Mbps Signalling Duration Measurement

Figure 3.5(b) describes the test circuit to verify that terminal equipment signals the network upon entering the off-hook state.

Back to document

Figure 3.6(a): 1.544 Mbps On-hook Level Measurement

Figure 3.6(a) describes the test circuit to verify the equivalent analog level content in the on-hook state for subrate, 1.544 Mb/s TE, 1.544 Mb/s protective circuitry and 1.544 Mb/s reverse battery.

Back to document

Figure 3.6(b): 1.544 Mbps Encoded Analog Content Measurement

Figure 3.6(b) describes the test circuit to verify the maximum equivalent power of the encoded analog content of the transmitted digital signal.

Back to document

Figure 3.6(c): 1.544 Mbps Signalling Interface Measurement

Figure 3.6(c) describes the test circuit to verify the signal power contained in the encoded analog signal in both the signalling band and in the guardband.

Back to document

Figure 3.6(d): Through Transmission (Digital) Measurement

Figure 3.6(d) describes the test circuit to verify that the through-transmission connections of the digital terminal equipment do not provide gain in excess of the limits in Section 3.6.5.1.

Back to document

Figure 3.6(e): Arrangement for Figures 3.6(d) and (f)

Figure 3.6(e) provides the digital terminal equipment arrangement for through transmission digital (see Figure 3.6(d)) and signal frequency guardbands digital measurements (see Figure 3.6(f)).

Back to document

Figure 3.6(f): Through Transmission (Signal Frequency Guardbands, Digital) Measurement

Figure 3.6(f) describes the test circuit to compare the insertion loss for digital equipment in the 800 Hz to 2450 Hz and 2450 Hz to 2750 Hz frequency bands.

Back to document